Model: PSH(-3+1)
Back to
Products
Video Show
Hydraulic Pit Lift Parking System, 3 cars in
the pit, 1 cars on the ground,
Work Principle
This system is designed with 4 levels, 3 in the pit, 1 on the ground, each column total 4 cars can lift up and down freely. The top car can go directly in and out; the pit cars can go in and out when they lift to the ground level; It has big pallets covering the top pit area. Total depth of pit will be 4260mm.
The pallet is 150mm higher
than the land level, it has a 1500mm
slopping way for the car parking, and it has
a tight cover with the ground frame against
water into the pit. It is designed with
water drainage system, maintenance entrance
with ladders.
The top car
pallet can be planted with grass and flowers
to keep a wonderful environmental
requirements.
Characteristics
It saves the land area and takes full use of the underground area. It can be designed with neighbored
multi-sets layout to raise the parking numbers of cars. The middle and bottom cars may have advantages of anti-dust, anti-rain, anti-theft. It is safe and reliable and easy in operation.
Low area coverage and high usage rate of
space;
The levels and columns will be added to
raise the number of cars according to
the customer's requirements;
It may be designed with full-closed
style to adjust the surrounding
environment;
It operates steadily without noise and
with fast operating speed and short
parking and releasing time;
Multi-ways of safety protection and
series of safety protection devices for
anti-dropping, anti-crashing and
anti-overloading.
Technical Parameters
Item | Parameters |
---|---|
Model |
PSH(-3+1) |
Levels of system |
4 |
Spaces |
Based on requirements |
Size of car (L*W*H) |
5000*1850*1550mm 5000*1850*2050mm |
Weight of car |
2000kg |
Motor power and speed |
Lift: 11KW, 12~18m/min |
Slide: 0.2kw, 8m/min |
|
Safeguard devices |
Hydraulic whole protection and anti-fall frame |
Modes of operation |
IC card reading / Manual button with keyboard |
Controller |
PLC |
Warning devices |
Sound, light, electricity |
Malfunction indication |
Fault diagnosis by computer, liquid crystal display |
Frame composition |
Columns and beams are made of H type steel, Channel steel, angle steel and square pipes; |
Parts appearance treatment |
Galvanized treatment and high-grade anti-corrosion painting |
Parking way |
Forward in, Back out |
Electricity |
3 phases 5 wires, 380V, 50HZ |